Home Page

A-Type | O-Type | D-Type | Deaerators | TFCH Heaters

TFCH-TF Heater :
The TFCH heater series is designed for high temperature hot water applications and also for high temperature thermal fluid applications. Its large furnace can be fired with any fuel. It will burn solid waste an open bottom furnace.
In a TFCH heater the fluid flow is controlled and balanced through each tube. Orifices are sometimes used to optimize flow distribution. Small diameter tubes are used with convection staggered tube arrangement to optimize heat transfer and flow distribution. The tubes are tangent in the furnace. A gas tight inner casing is provided to ensure a gas tight envelope.
The clients for high temperature hot water applications will be institutional like cities, universities, airports, military bases, where a central boiler room is used to distribute heat to a great number of buildings like in district heating.
It applies also to larger capacities than the Aquatube boiler series. The largest size of Aquatube provides 40millions BTU/hr where as the TFCH can go as high as 150millions BTU/hr in a single unit. The TFCH needs a pump to maintain a minimum flow in the unit at all time.
The thermal fluid applications will be clients like petrochemical industries ,wood processing industries ,mines, food processing etc, where the fluid temperature must be very high like 550F to 600F (288C to 315C)and must be accurately maintain around the set point. Steam or hot water can be produced by adding heat exchanger.

Thermoboil forced circulation high temperature thermal fluid:

Heater series:
TFCH-TF

Capacity:
From 10 to 150millions BTU/hr

Fuels: Natural gas, #2 oil, #6oil

Construction: ASME section I

 

Physical Data  "TFCH-TF" :

Thermal fluid ,Thermoboil forced circulation heater:

Side Elevation Plan View

Front View
 

10 12.5 15 20 25 30 35 40 45 50 55 62.5 75
BTU Output
M kcal/hr 
2025 2525 3050 4050 5050 6075 7075 8100 9100 10100 11375 12650 15175
A-overall
base length
4420 4395 4800 5335 5335 6020 6175 6325 6785 7265 7470 7545 7620
B-overall
base width
1220 1450 1575 1730 2160 2440 2440 2440 2440 2540 2540 2540 3000
C-
overall
width
1905 2135 2260 2415 2845 3125 3125 3125 3125 3225 3225 3225 3685
D-Flue
gas outlet height
2770 2770 2770 2770 2770 2770 2970 2970 2970 3125 3125 3380 3660
E-Inlet &
Outlet
FLG size

(imperial pipe size)
6" 6" 8" 8" 8" 10" 10" 10" 10" 10" 10" 10" 10"
F-Inlet flange height 2795 2795 2795 2795 2795 2795 3000 3000 3000 3150 3150 3405 3685
G-Outlet
flange height
3200 3200 3200 3200 3200 3200 3430 3430 3430 3585 3585 3835 4115
H-
Flue gas outlet location
685 685 735 815 815 865 990 990 1145 1195 1220 1295 1220
J-
Flue gas outlet length
1065 1065 1170 1345 1345 1450 1675 1675 1980 2060 2110 2285 2110
K-Flue gas outlet width 1070 1320 1400 1575 2005 2260 2260 2260 2260 2390 2390 2390 2845
Approx shipping wt(kg) 10500 13500 14000 16500 19500 22500 24500 27500 28500 31500 33500 36000 41000

*All dimensions are metric.

TFCH-W  Heater :
The TFCH heater series is designed for high temperature hot water applications and also for high temperature thermal fluid applications. Its large furnace can be fired with any fuel. It will burn solid waste an open bottom furnace.
In a TFCH heater the fluid flow is controlled and balanced through each tube. Orifices are sometimes used to optimize flow distribution. Small diameter tubes are used with convection staggered tube arrangement to optimize heat transfer and flow distribution. The tubes are tangent in the furnace. A gas tight inner casing is provided to ensure a gas tight envelope.
The clients for high temperature hot water applications will be institutional like cities, universities, airports, military bases, where a central boiler room is used to distribute heat to a great number of buildings like in district heating.
It applies also to larger capacities than the Aquatube boiler series. The largest size of Aquatube provides 40millions BTU/hr where as the TFCH can go as high as 150millions BTU/hr in a single unit. The TFCH needs a pump to maintain a minimum flow in the unit at all time.
The thermal fluid applications will be clients like petrochemical industries ,wood processing industries ,mines, food processing etc, where the fluid temperature must be very high like 550F to 600F (288C to 315C)and must be accurately maintain around the set point. Steam or hot water can be produced by adding heat exchanger.

Thermoboil forced circulation high temperature hot water :

Heater series: TFCH-W

Capacity:
From 10 to 150millions BTU/hr

Fuels: Natural gas, #2 oil, #6 oil

Construction: ASME section I

 

Physical Data  "TFCH-W" :
High Temperature Hot Water  ,Thermoboil forced circulation heater:
 
Side Elevation
 
Plan View
Front View  

Generator Model: TFCH-HW 10 12.5 15 20 25 30 35 40 45 50 55 62.5 75
BTU Output
M kcal/hr 
2525 3175 3800 5050 6325 7600 8850 10100 11375 12650 14000 15800 18950
A-overall
base length
4420 4395 4800 5335 5335 6020 6175 6325 6785 7265 7470 7545 7620
B-overall
base width
1220 1450 1575 1730 2160 2440 2440 2440 2440 2540 2540 2540 3000
C-overall
width
1905 2135 2260 2415 2845 3125 3125 3125 3125 3225 3225 3225 3685
D-Flue
gas outlet height
2770 2770 2770 2770 2770 2770 2970 2970 2970 3125 3125 3380 3660
E-Inlet &
Outlet FLG size
(imperial pipe size)
6" 6" 8" 8" 8" 10" 10" 10" 10" 10" 10" 10" 10"
F-Inlet flange height 2795 2795 2795 2795 2795 2795 3000 3000 3000 3150 3150 3405 3685
G-Outlet
flange height
3200 3200 3200 3200 3200 3200 3430 3430 3430 3585 3585 3835 4115
H-Flue gas outlet location 685 685 735 815 815 865 990 990 1145 1195 1220 1295 1220
J-Flue gas outlet length 1065 1065 1170 1345 1345 1450 1675 1675 1980 2060 2110 2285 2110
K-Flue gas outlet width 1070 1320 1400 1575 2005 2260 2260 2260 2260 2390 2390 2390 2845
Approx shipping wt(kg) 10500 13500 14000 16500 19500 22500 24500 27500 28500 31500 33500 36000 41000

*All dimensions are in millimeter except as noted. go to top