TFCH-TF Heater :
The TFCH heater
series is designed for high temperature
hot water applications and also for
high temperature thermal fluid applications.
Its large furnace can be fired with
any fuel. It will burn solid waste an
open bottom furnace.
In a TFCH heater the fluid flow is controlled
and balanced through each tube. Orifices
are sometimes used to optimize flow
distribution. Small diameter tubes are
used with convection staggered tube
arrangement to optimize heat transfer
and flow distribution. The tubes are
tangent in the furnace. A gas tight
inner casing is provided to ensure a
gas tight envelope.
The clients for high temperature hot
water applications will be institutional
like cities, universities, airports,
military bases, where a central boiler
room is used to distribute heat to a
great number of buildings like in district
heating.
It applies also to larger capacities
than the Aquatube boiler series. The
largest size of Aquatube provides 40millions
BTU/hr where as the TFCH can go as high
as 150millions BTU/hr in a single unit.
The TFCH needs a pump to maintain a
minimum flow in the unit at all time.
The thermal fluid applications will
be clients like petrochemical industries
,wood processing industries ,mines,
food processing etc, where the fluid
temperature must be very high like 550F
to 600F (288C to 315C)and must be accurately
maintain around the set point. Steam
or hot water can be produced by adding
heat exchanger.
Thermoboil
forced circulation high temperature
thermal fluid:
Heater series: TFCH-TF
Capacity:
From 10 to
150millions BTU/hr
Fuels:
Natural gas,
#2 oil, #6oil
Construction:
ASME section
I
Physical Data
"TFCH-TF" :
Thermal fluid ,Thermoboil forced circulation heater:
10 |
12.5 |
15 |
20 |
25 |
30 |
35 |
40 |
45 |
50 |
55 |
62.5 |
75 |
BTU
Output
M kcal/hr
|
2025 |
2525 |
3050 |
4050 |
5050 |
6075 |
7075 |
8100 |
9100 |
10100 |
11375 |
12650 |
15175 |
A-overall
base length |
4420 |
4395 |
4800 |
5335 |
5335 |
6020 |
6175 |
6325 |
6785 |
7265 |
7470 |
7545 |
7620 |
B-overall
base width |
1220 |
1450 |
1575 |
1730 |
2160 |
2440 |
2440 |
2440 |
2440 |
2540 |
2540 |
2540 |
3000 |
C-
overall
width |
1905 |
2135 |
2260 |
2415 |
2845 |
3125 |
3125 |
3125 |
3125 |
3225 |
3225 |
3225 |
3685 |
D-Flue
gas outlet height |
2770 |
2770 |
2770 |
2770 |
2770 |
2770 |
2970 |
2970 |
2970 |
3125 |
3125 |
3380 |
3660 |
E-Inlet
&
Outlet
FLG size
(imperial
pipe size) |
6" |
6" |
8" |
8" |
8" |
10" |
10" |
10" |
10" |
10" |
10" |
10" |
10" |
F-Inlet
flange height |
2795 |
2795 |
2795 |
2795 |
2795 |
2795 |
3000 |
3000 |
3000 |
3150 |
3150 |
3405 |
3685 |
G-Outlet
flange height |
3200 |
3200 |
3200 |
3200 |
3200 |
3200 |
3430 |
3430 |
3430 |
3585 |
3585 |
3835 |
4115 |
H-
Flue gas outlet location |
685 |
685 |
735 |
815 |
815 |
865 |
990 |
990 |
1145 |
1195 |
1220 |
1295 |
1220 |
J-
Flue gas outlet length |
1065 |
1065 |
1170 |
1345 |
1345 |
1450 |
1675 |
1675 |
1980 |
2060 |
2110 |
2285 |
2110 |
K-Flue
gas outlet width |
1070 |
1320 |
1400 |
1575 |
2005 |
2260 |
2260 |
2260 |
2260 |
2390 |
2390 |
2390 |
2845 |
Approx
shipping wt(kg) |
10500 |
13500 |
14000 |
16500 |
19500 |
22500 |
24500 |
27500 |
28500 |
31500 |
33500 |
36000 |
41000 |
*All dimensions
are metric.
TFCH-W Heater :
The TFCH heater
series is designed for high temperature
hot water applications and also for
high temperature thermal fluid applications.
Its large furnace can be fired with
any fuel. It will burn solid waste an
open bottom furnace.
In a TFCH heater the fluid flow is controlled
and balanced through each tube. Orifices
are sometimes used to optimize flow
distribution. Small diameter tubes are
used with convection staggered tube
arrangement to optimize heat transfer
and flow distribution. The tubes are
tangent in the furnace. A gas tight
inner casing is provided to ensure a
gas tight envelope.
The clients for high temperature hot
water applications will be institutional
like cities, universities, airports,
military bases, where a central boiler
room is used to distribute heat to a
great number of buildings like in district
heating.
It applies also to larger capacities
than the Aquatube boiler series. The
largest size of Aquatube provides 40millions
BTU/hr where as the TFCH can go as high
as 150millions BTU/hr in a single unit.
The TFCH needs a pump to maintain a
minimum flow in the unit at all time.
The thermal fluid applications will
be clients like petrochemical industries
,wood processing industries ,mines,
food processing etc, where the fluid
temperature must be very high like 550F
to 600F (288C to 315C)and must be accurately
maintain around the set point. Steam
or hot water can be produced by adding
heat exchanger.
Thermoboil forced
circulation high temperature hot water :
Heater series: TFCH-W
Capacity:
From 10 to 150millions BTU/hr
Fuels:
Natural gas,
#2 oil, #6 oil
Construction:
ASME section
I
Physical Data
"TFCH-W" :
High Temperature
Hot Water ,Thermoboil forced
circulation heater:
Generator
Model: TFCH-HW |
10 |
12.5 |
15 |
20 |
25 |
30 |
35 |
40 |
45 |
50 |
55 |
62.5 |
75 |
BTU
Output
M kcal/hr
|
2525 |
3175 |
3800 |
5050 |
6325 |
7600 |
8850 |
10100 |
11375 |
12650 |
14000 |
15800 |
18950 |
A-overall
base length |
4420 |
4395 |
4800 |
5335 |
5335 |
6020 |
6175 |
6325 |
6785 |
7265 |
7470 |
7545 |
7620 |
B-overall
base width |
1220 |
1450 |
1575 |
1730 |
2160 |
2440 |
2440 |
2440 |
2440 |
2540 |
2540 |
2540 |
3000 |
C-overall
width |
1905 |
2135 |
2260 |
2415 |
2845 |
3125 |
3125 |
3125 |
3125 |
3225 |
3225 |
3225 |
3685 |
D-Flue
gas outlet height |
2770 |
2770 |
2770 |
2770 |
2770 |
2770 |
2970 |
2970 |
2970 |
3125 |
3125 |
3380 |
3660 |
E-Inlet
&
Outlet FLG size
(imperial pipe size)
|
6" |
6" |
8" |
8" |
8" |
10" |
10" |
10" |
10" |
10" |
10" |
10" |
10" |
F-Inlet
flange height |
2795 |
2795 |
2795 |
2795 |
2795 |
2795 |
3000 |
3000 |
3000 |
3150 |
3150 |
3405 |
3685 |
G-Outlet
flange height |
3200 |
3200 |
3200 |
3200 |
3200 |
3200 |
3430 |
3430 |
3430 |
3585 |
3585 |
3835 |
4115 |
H-Flue
gas outlet location |
685 |
685 |
735 |
815 |
815 |
865 |
990 |
990 |
1145 |
1195 |
1220 |
1295 |
1220 |
J-Flue
gas outlet length |
1065 |
1065 |
1170 |
1345 |
1345 |
1450 |
1675 |
1675 |
1980 |
2060 |
2110 |
2285 |
2110 |
K-Flue
gas outlet width |
1070 |
1320 |
1400 |
1575 |
2005 |
2260 |
2260 |
2260 |
2260 |
2390 |
2390 |
2390 |
2845 |
Approx
shipping wt(kg) |
10500 |
13500 |
14000 |
16500 |
19500 |
22500 |
24500 |
27500 |
28500 |
31500 |
33500 |
36000 |
41000 |
*All dimensions
are in millimeter except as noted.